FPGA-Based Fieldbus Interfaces

FPGA-based fieldbus connections with PCI and PCI Express for fast, deterministic communication in industrial control and measurement systems.

Block diagram: PC connected via PCI/PCIe to an FPGA with IP core, controller, dual-port RAM and fieldbus interface, linked to a fieldbus controller for PROFINET and PROFIBUS

Fast, deterministic communication between PC systems and industrial fieldbuses.

Fast control loops and time-critical measurement and test systems need short, reproducible communication cycles. We develop FPGA-based interfaces that connect PC and embedded systems to industrial fieldbuses via PCI or PCI Express – with cycle times below 100 µs and precise timing.

Architecture

The FPGA connects the host system to the fieldbus and handles data transport, sequence control and synchronization (see diagram above):

  • PCI/PCIe IP core with bus master/DMA for the host connection
  • Controller for control, timing and communication sequences
  • Dual-port RAM as a buffer that decouples the host and fieldbus sides
  • Fieldbus interface to an external communication controller, or with a custom protocol directly in the FPGA

Fast and Deterministic

Using PCI bus master accesses, the interface transfers data to and from host memory on its own. The processor does not have to move every data word itself – resulting in high throughput with low CPU load.

Because time-critical sequences run in hardware, they are independent of the host operating system. This makes cycle frequencies of more than 10 kHz possible:

  • short communication and processing times
  • reproducible timing with low jitter
  • parallel processing of multiple communication functions

The cycle time actually achievable also depends on the fieldbus protocol and the connected devices.

Flexible in Fieldbus and Platform

We connect complex protocols such as PROFINET or PROFIBUS via a specialized fieldbus controller. Simpler protocols are implemented directly in the FPGA – eliminating the need for an additional controller. Thanks to the modular architecture, switching to a different fieldbus standard does not require a complete redevelopment.

The interface can be implemented as a PCI or PCIe plug-in card for industrial PCs or integrated directly on an embedded PC board – with short signal paths and close coupling of host, FPGA and fieldbus hardware.

Technical Data

  • Cycle frequency > 10 kHz (cycle time < 100 µs)
  • Host connection via PCI or PCI Express with bus master/DMA
  • PROFINET and PROFIBUS via external fieldbus controller
  • Custom communication protocols directly in the FPGA
  • FPGA development in VHDL
  • As plug-in card or on embedded PC board

Interested?

Are you looking for a fast fieldbus solution for your control application? Send us your inquiry.